Biocide Close Loop

Closed Loop Biocides, chilled water prevent and eradicate unwanted biological fouling from the system.

SKU: RXSOL-40-4008-027 Category:

Description

RXSOL-40-4008-027 Biocides is chemical  that prevent and eradicate unwanted biological fouling from the system. Biocides are of various nature such as oxidizing, non-oxidizing, cationic, anionic etc. Biological Fouling or Biofouling is the undesirable accumulation of micro-organisms, algae and diatoms, plants, and animals on surface, pipelines and heat-exchangers of cooling systems. Bio-fouling can be of aerobic (that require oxygen) or anerobic (that don’t require oxygen) organisms. In general the former is found in Cooling Towers and the later in closed circuit systems.

Another very important reason for using RXSOL-40-4008-027 Biocides in cooling towers is to prevent the growth of Legionella, including species that cause legionellosis or Legionnaires’ disease, most notably L. pneumophila, or Mycobacterium avium. The various Legionella species are the cause of Legionnaires’ disease in humans and transmission is via exposure to aerosols—the inhalation of mist droplets containing the bacteria. Common sources of Legionella include cooling towers used in open recirculating evaporative cooling water systems, domestic hot water systems, fountains, and similar disseminators that tap into a public water supply.

RXSOL-40-4008-027  biocides function in eradication of sulfate reducing bacteria, aerobic and anaerobic bacteria that are formed and found in Cooling Tower Water.Micro Biocides are very vital for Closed and Open Circuit Cooling Water Treatment.

TCF (Totally Chlorine Free) micro biocides are compatible with heat transfer fluids (HTF) and can be used without any fear of corrosion of chlorine addition to the system or depletion or degradation of HTF and corrosion of PHE (plate type heat exchangers)

 

 


 

Technical Bulletin

Description :

RXSOL-40-4008-027 Biocides is chemical  that prevent and eradicate unwanted biological fouling from the system. Biocides are of various nature such as oxidizing, non-oxidizing, cationic, anionic etc. Biological Fouling or Biofouling is the undesirable accumulation of micro-organisms, algae and diatoms, plants, and animals on surface, pipelines and heat-exchangers of cooling systems. Bio-fouling can be of aerobic (that require oxygen) or anerobic (that don’t require oxygen) organisms. In general the former is found in Cooling Towers and the later in closed circuit systems.

Another very important reason for using RXSOL-40-4008-027 Biocides in cooling towers is to prevent the growth of Legionella, including species that cause legionellosis or Legionnaires’ disease, most notably L. pneumophila, or Mycobacterium avium. The various Legionella species are the cause of Legionnaires’ disease in humans and transmission is via exposure to aerosols—the inhalation of mist droplets containing the bacteria. Common sources of Legionella include cooling towers used in open recirculating evaporative cooling water systems, domestic hot water systems, fountains, and similar disseminators that tap into a public water supply.

RXSOL-40-4008-027  biocides function in eradication of sulfate reducing bacteria, aerobic and anaerobic bacteria that are formed and found in Cooling Tower Water.Micro Biocides are very vital for Closed and Open Circuit Cooling Water Treatment.

TCF (Totally Chlorine Free) micro biocides are compatible with heat transfer fluids (HTF) and can be used without any fear of corrosion of chlorine addition to the system or depletion or degradation of HTF and corrosion of PHE (plate type heat exchangers).

Application and Dose :

Engine Jacket, Chiller Water Circuit, Glycol Brine System, Hot Water Circuit, Engine Coolant, Process chilling and heating etc.

Dosage:
The amount of Closed Loop Biocide required to inhibit or remove bio fouling depends on the type of system, application, re-circulating fluid property and plant operating conditions. The specific dosage rates will be specified by the CSL technical representative.

Physical Properties  :

Chemical Type   :   Organic/Inorganic Chemical Compound (TCF).
Form                     :   Liquid.
Specific Gravity   :   Ranges from 1.0 – 1.2 depending upon product
Solubility              :   Completely Soluble in Water.

Advantage / Benifit :

  •     Prevention of Bio-fouling of system.
  •     Avoid plugging of nozzles.
  •     Avoids MIC (Microbiologically Induced Corrosion).
  •     Prevent Water Borne Diseases.
  •     Improve heat loss because living organisms cause rise in temperature of water.
  •     Does not add chloride to the system.

Label