Boiler Coagulant Sludge Conditioner

A concentrated solution of surface-active polymers which is use as an internal sludge conditioners in boilers. Boiler Coagulant is a colorless, high molecular weight solution used in both medium and low-pressure boilers (<850 psig or 60 kg/cm2)

SKU: RXSOL-50-5003-025 Category:

Description

To prevent oil sludge deposits when feedwater becomes contaminated by oil. Boiler Coagulant prevents the formation of deposits on boiler internal surfaces. Sludge is kept dispersed in small particles and conditioned to be removed by normal blowdown. In this way tube overheating due to deposits is avoided.

RXSOL-50-5003-025 eliminate light oil contamination, A concentrated solution of surface-active polymers which is use as an internal sludge conditioners in boilers. Boiler Coagulant  is a colorless, high molecular weight solution used in both medium and low-pressure boilers (<850 psig or 60 kg/cm2

Technical Bulletin

Boiler Coagulant –  Boiler Sludge Conditioner

RXSOL-50-5003-025

Description

Boiler Coagulant  is a colorless, high molecular weight solution used in both medium and low-pressure boilers (<850 psig or 60 kg/cm2) to prevent oil sludge deposits when feedwater becomes contaminated by oil. Boiler Coagulant prevents the formation of deposits on boiler internal surfaces. Sludge is kept dispersed in small particles and conditioned to be removed by normal blowdown. In this way tube overheating due to deposits is avoided.

Application

Boiler Coagulant can also be used where minor oil contamination has been experienced, the oil being required to be coagulated for removal by blowdown. However, it must be noted that if oil contamination is continuous and excessive, off-line cleaning will be required. The source of oil contamination must be stopped immediately.

Dosage:

Boiler Coagulant  initial dosage is 25 ml of treatment daily for every ton of boiler capacity. Daily bottom blowdown is required when using Boiler Coagulant.It must be dosed to boiler water that is maintained in an alkaline condition. For systems experiencing severe oil contamination, off-line cleaning is desirable. After the equipment is cleaned, dose rate of 25 mls per day per ton of water capacity for two weeks or until complete oil removal is accomplished. If severity of contamination persists, the possibility of additional oil in leakage should be investigated and eliminated.

Feeding: Boiler Coagulant  may be dissolved with other boiler treatment chemicals and fed directly to the boiler by means of a bypass pot feeder or suitable chemical injection pump. For lowpressure boilers, the solution may be dosed to the hotwell or the condensate return tank.

Physical  Properties

Appearance: Clear liquid / slight yellow

Specific Gravity at 25° C (77° F): 1.12

pH: 6.9 – 8.5

Packing : 25 Ltrs.

Features and Benefit

  • Liquid product, easy to feed.
  • Prevents the formation of adherent deposits and sludges in boilers.
  • Keeps sludge dispersed for efficient removal by blowdown.
  • Keeps boilers clean and extends boiler operational time between cleaning.
  • Used in conjunction with any products with RXSOL boiler water treatments.
  • Used to coagulate small amounts of oil which have contaminated the boiler water.

Label

Boiler Coagulant is a colorless, high molecular weight solution used in both medium- and low-pressure boilers (<850 psig or 60 kg/cm2) to prevent oil sludge deposits when feedwater becomes contaminated by oil. Boiler Coagulant prevents the formation of deposits on boiler internal surfaces. Sludge is kept dispersed in small particles and conditioned to be removed by normal blowdown. In this way tube overheating due to deposits is avoided. LABEL PROPERTY

Not classified as dangerous for users
S2: Keep out the reach of children

PROPER SHIPPING NAME: Not Regulated
UN Number : —-
Class : –
Packing Group : —
EmS:-
Marine pollutant: No

WhatsApp chat